Tempco's Jack Panels are made from rugged, .090" thick
aluminum and allow for easy installation of multi-circuit thermocouple
or RTD Quick Disconnect Jacks in your panel or housing. Panels can be
manufactured with either a single calibration type or a mixed variety.
|
|
Jack
Panels |
Rack
Panels/FS Box |
Selector
Switches/Std. & Circular Panel Jacks |
|

|

|
 
|
|
   |
Accepts standard plugs.
Jacks are ANSI color coded, glass filled nylon with a maximum
service temperature of 400ºF (204ºC).
Panels are manufactured from rugged, .090" thick aluminum.
Brushed and anodized finishes are available at an additional
cost. Consult TEMPCO with your requirements.
Panels are normally supplied unassembled with
all necessary hardware to assemble and install included. Can be
furnished assembled at an additional cost.
Standard Sizes |
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
|
JP(¤)00001
|
1
|
3-1/2 x 10
|
12
|
1-7/8 x 9-1/4
|
|
JP(¤)00002
|
2
|
5-3/16 x 10
|
24
|
3-9/16 x 9-1/4
|
|
JP(¤)00003
|
3
|
8-1/8 x 10
|
36
|
6-1/2 x 9-1/4
|
|
JP(¤)00004
|
4
|
9-7/8 x 10
|
48
|
8-1/4 x 9-1/4
|
|
JP(¤)00005
|
5
|
12-3/4 x 10
|
60
|
11-1/8 x 9-1/4
|
|
JP(¤)00006
|
6
|
14-9/16 x 10
|
72
|
12-15/16 x 9-1/4
|
|
¤ Insert
calibration code in Part Number (J, K, T, E, R, S, U, N) |
|
Mounting Hole Spacing: 3/16" in from
each side to center of 13/64" hole (for #10 screw).
Bezel Panel Jacks are retained by a spring clip which is
installed from the rear of the panel.
Wire may be attached after Jacks are installed in panel. |
|
|
|

Standard Sizes
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
|
JP(¤)00007
|
1
|
3-1/2 x 5-1/2
|
6
|
1-7/8 x 4-21/32
|
|
JP(¤)00008
|
2
|
5-3/16 x 5-1/2
|
12
|
3-9/16 x 4-21/32
|
|
JP(¤)00009
|
3
|
8-1/8 x 5-1/2
|
18
|
6-1/2 x 4-21/32
|
|
JP(¤)00010
|
4
|
9-7/8 x 5-1/2
|
24
|
8-1/4 x 4-21/32
|
|
JP(¤)00011
|
5
|
12-3/4 x 5-1/2
|
30
|
11-1/8 x 4-21/32
|
|
JP(¤)00012
|
6
|
14-9/16 x 5-1/2
|
36
|
12-15/16 x 4-21/32
|
¤ Insert calibration
code in Part Number (J, K, T, E, R, S, U, N)
|
|
|
Designed to be space saving.
Complements modern miniature instrumentation.
Jack bodies are ANSI color coded, glass filled nylon with a
maximum service
temperature of 400ºF (204ºC).
Panels are manufactured of rugged .090" thick aluminum.
Brushed and anodized finishes are available at an additional
cost. Consult TEMPCO
with your requirements.
Panels are supplied unassembled for ease of wiring--all
hardware to assemble is included. |
|
|
|

|
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
Price
US Dollars |
|
JP(¤)00013
|
1
|
22-1/32 x 3-5/8
|
6
|
1-9/32 x 3-3/32
|
|
|
JP(¤)00014
|
2
|
4-5/16 x 3-5/8
|
12
|
2-15/16 x 3-3/32
|
|
|
JP(¤)00015
|
3
|
5-31/32 x 3-5/8
|
18
|
4-19/32 x 3-3/32
|
|
|
JP(¤)00016
|
4
|
7-5/8 x 3-5/8
|
24
|
6-1/4 x 3-3/32
|
|
|
JP(¤)00017
|
1
|
2-21/32 x 6-5/8
|
12
|
1-9/32 x 6-1/16
|
|
|
JP(¤)00018
|
2
|
4-5/16 x 6-5/8
|
24
|
2-15/16 x 6-1/16
|
|
|
JP(¤)00019
|
3
|
5-31/32 x 6-5/8
|
36
|
4-19/32 x 6-1/16
|
|
|
JP(¤)00020
|
4
|
7-5/8 x 6-5/8
|
48
|
6-1/4 x 6-1/16
|
|
¤ Insert calibration
code in Part Number (J, K, T, E, R, S, U)
|
|
|
 |
|
Mounting Hole Spacing: 3/16" in from
each side to center of 13/64" hole (for #10 screw).
|
|
|
|
|
|
For Standard 3-pin
Connectors
 |
|
For use with RTD's and shielded thermocouples requiring 3
wires.
Will accept standard 3-Pin connectors.
Jack bodies are ANSI color coded, glass filled nylon with a
maximum service temperature of 400ºF (204ºC).
Panels are manufactured of rugged .090" thick aluminum.
Brushed and anodized finishes are available at an additional
cost. Consult TEMPCO with your requirements.
Panels are supplied unassembled for ease of wiring--all
hardware to assemble is included.
|
|
|
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
|
JP(¤)00021
|
1
|
3-1/2 x 5-1/4
|
6
|
2-3/32 x 4-15/32
|
|
JP(¤)00022
|
2
|
6-1/32 x 5-1/4
|
12
|
4-21/32 x 4-15/32
|
|
JP(¤)00023
|
3
|
8-19/32 x 5-1/4
|
18
|
7-9/32 x 4-15/32
|
|
JP(¤)00024
|
4
|
11-5/32 x 5-1/4
|
24
|
9-25/32 x 4-15/32
|
|
JP(¤)00025
|
1
|
3-1/2 x 9-3/4
|
12
|
2-3/32 x 8-31/32
|
|
JP(¤)00026
|
2
|
6-1/32 x 9-3/4
|
24
|
4-21/32 x 8-31/32
|
|
JP(¤)00027
|
3
|
8-19/32 x 9-3/4
|
36
|
7-9/32 x 8-31/32
|
|
JP(¤)00028
|
4
|
11-5/32 x 9-3/4
|
48
|
9-25/32 x 8-31/32
|
|
¤ Insert
calibration code in Part Number (J, K, T, E, R, S, U) |
|
Mounting Hole Spacing: 3/16" in from each side
to center of 13/64" hole (for #10 screw). |
|
|
|
|
For use with RTD's and shielded thermocouples requiring 3
wires. Complements modern miniature instrumentation. Jack bodies are ANSI color coded, glass filled nylon with a
maximum service temperature of 400ºF (204ºC). Panels are manufactured of rugged .090" thick aluminum. Brushed and anodized finishes are available at an additional
cost. Consult TEMPCO with your requirements. Panels are supplied unassembled for ease of wiring--all
hardware to assemble is included.
|
|
Standard Sizes |
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
|
JP(¤)00029
|
1
|
2-15/16 x 4-3/4
|
6
|
1-9/16 x 4-5/32
|
|
JP(¤)00030
|
2
|
4-15/16 x 4-3/4
|
12
|
3-9/16 x 4-5/32
|
|
JP(¤)00031
|
3
|
6-15/16 x 4-3/4
|
18
|
5-9/16 x 4-5/32
|
|
JP(¤)00032
|
4
|
8-15/16 x 4-3/4
|
24
|
7-9/16 x 4-5/32
|
|
JP(¤)00033
|
1
|
2-15/16 x 9
|
12
|
1-9/16 x 8-15/32
|
|
JP(¤)00034
|
2
|
4-15/16 x 9
|
24
|
3-9/16 x 8-15/32
|
|
JP(¤)00035
|
3
|
6-15/16 x 9
|
36
|
5-9/16 x 8-15/32
|
|
JP(¤)00036
|
4
|
8-15/16 x 9
|
48
|
7-9/16 x 8-15/32
|
|
¤ Insert
calibration code in Part Number (J, K, T, E, R, S, U)
Mounting Hole Spacing: 3/16" in from each side
to center of 13/64" hole (for #10 screw).
|
|
|
Selector Switches |
|

Available in 6 to 36 positions 2-Pole and 3-Pole circuits with "OFF" position Silver plated blades and contacts with self-cleaning
wiper action and low contact resistance Terminals are silver plated brass with numbered
circuits and polarity identification "OFF" position has terminals available for
shorting input circuit when using it with a digital meter
(Not available on 3-Pole) High impact GE noryl™ case
|

|
|
|
|
Number of
Positions
|
Circuit Type
|
Part
Number
|
Size |
|
6
|
2-Pole
Break Before Make
|
TCA-124-101
|
Size "A"
|
|
10
|
TCA-124-102
|
|
12
|
2-Pole
Make Before Break
|
TCA-124-103
|
|
18
|
TCA-124-104
|
|
20
|
TCA-124-105
|
|
24
|
2-Pole
Make Before Break
|
TCA-124-106
|
Size "B"
|
|
36
|
TCA-124-107
|
|
6
|
3-Pole
Make Before Break
|
TCA-124-108
|
|
12
|
TCA-124-109
|
|
18
|
TCA-124-110
|
|
24
|
TCA-124-111
|
|
|
|
|
Standard Jack |
Miniature Jack |
|
|
Available in standard and miniature sizes (2-pin
only).
Used where individual Jacks are required to fit in
standard electrical knockouts.
Standard Jack fits in 3/4" (1-1/8" dia.)
electrical knockout.
Miniature Jack fits in 1/2" (7/8" dia.)
electrical knockout.
Jacks are ANSI color coded with a maximum service
temperature of 400ºF (204ºC).
Both the standard and miniature Jacks install from
the front of the panel with no additional hardware required.
ANSI
Calibration |
Body Color
|
Part
Number
Standard |
Miniature
|
|
J
|
Black
|
TCA-102-167
|
TCA-102-174
|
|
K
|
Yellow
|
TCA-102-168
|
TCA-102-175
|
|
T
|
Blue
|
TCA-102-169
|
TCA-102-176
|
|
E
|
Purple
|
TCA-102-170
|
TCA-102-177
|
|
R/S
|
Green
|
TCA-102-171
|
TCA-102-178
|
|
Cu
|
White
|
TCA-102-172
|
TCA-102-179
|
|
N
|
Orange
|
TCA-102-173
|
--
|
|
|
Panel Jacks
All Panel Jacks have the same high quality features
as their non-panel counterparts and include hardware for mounting. |
|
Bezel
Mount
Standard
Jack |
|
|

|

|
|
ANSI
Calibration
|
Body Color
|
Part
Number
|
|
J
|
Black
|
TCA-102-137
|
|
K
|
Yellow
|
TCA-102-138
|
|
T
|
Blue
|
TCA-102-139
|
|
E
|
Purple
|
TCA-102-140
|
|
R/S
|
Green
|
TCA-102-141
|
|
Cu
|
White
|
TCA-102-142
|
|
N
|
Orange
|
TCA-102-180
|
|
|
Miniature Panel Jack -- 2-Pin |
|
|

|

|
|
ANSI
Calibration
|
Body Color
|
Part
Number
|
|
J
|
Black
|
TCA-102-143
|
|
K
|
Yellow
|
TCA-102-144
|
|
T
|
Blue
|
TCA-102-145
|
|
E
|
Purple
|
TCA-102-146
|
|
R/S
|
Green
|
TCA-102-147
|
|
Cu
|
White
|
TCA-102-148
|
|
|
Standard 3-Pin Panel Jack |
|
|

|

|
|
ANSI
Calibration
|
Body Color
|
Part
Number
|
|
J
|
Black
|
TCA-102-149
|
|
K
|
Yellow
|
TCA-102-150
|
|
T
|
Blue
|
TCA-102-151
|
|
E
|
Purple
|
TCA-102-152
|
|
R/S
|
Green
|
TCA-102-153
|
|
Cu
|
White
|
TCA-102-154
|
|
|
Miniature Panel Jack -- 3-Pin |
|
|

|

|
|
ANSI
Calibration
|
Body Color
|
Part
Number
|
|
J
|
Black
|
TCA-102-155
|
|
K
|
Yellow
|
TCA-102-156
|
|
T
|
Blue
|
TCA-102-157
|
|
E
|
Purple
|
TCA-102-158
|
|
R/S
|
Green
|
TCA-102-159
|
|
Cu
|
White
|
TCA-102-160
|
|
|
Panel Mount Standard Jab-In Jack
|
|
|
 |
 |
|
ANSI
Calibration
|
Body Color
|
Part
Number
|
|
J
|
Black
|
TCA-102-161
|
|
K
|
Yellow
|
TCA-102-162
|
|
T
|
Blue
|
TCA-102-163
|
|
E
|
Purple
|
TCA-102-164
|
|
R/S
|
Green
|
TCA-102-165
|
|
Cu
|
White
|
TCA-102-166
|
|
|
For FS Box
|
|
|
Panel Only
|
 |
Panel and
Box Assembly |
|
|
Jack Panels are designed to be used with standard FS Style
boxes.
Panels are manufactured of rugged .090" thick aluminum.
Panels are designed to accept the safest maximum number of
Jacks--see table.
Available for Standard and Miniature Jacks, 2-pin or 3-pin.
Rated for a maximum of 400ºF (204ºC).
Panels measure 2-13/16" high x 4-1/2" long.
|
|
Jack
Style
|
Part
Number
|
Number of
Jacks
|
|
Standard 2 Pin
Bezel Mount
|
JP(¤)00043
|
4
|
|
Standard 2 Pin
Jab-In Mount
|
JP(¤)00044
|
4
|
|
Standard 3 Pin
|
JP(¤)00045
|
4
|
|
Miniature 2 Pin
|
JP(¤)00046
|
6
|
|
Miniature 3 Pin
|
JP(¤)00047
|
4
|
¤ Insert
calibration code in Part Number (J, K, T, E, R, S, U)
|
|
|
|


|
Standard Features
Panels are made of .090" thick aluminum with a smooth mill
finish.
All panels have slotted holes positioned at E.I.A. standard spacing.
Panels are available with any of the standard or miniature Panel
Jacks shown in this section.
Rack Panels come in standard heights of 3-1/2", 5-1/4", 7", and
8-1/4".
Panels are supplied unassembled for ease of wiring--all hardware to
assemble is included.
|
|
|
|
To help ease
installation
Optional Ratchet Screwdriver
Part Number:
TUL-101-101 |
 |
|
|
 |
Accepts Standard Plugs.
Jacks will accept up to 14 gauge wire.
Jack bodies are ANSI color coded, glass filled nylon with a
maximum service temperature of 400ºF (204ºC).
Panels are manufactured of rugged .090" thick aluminum.
Brushed and anodized finishes are available at an additional
cost. Consult TEMPCO with your requirements.
Jack rows are placed further apart than standard Jack Panels
for ease of termination.
Panels are supplied unassembled for ease of wiring--all
hardware to assemble is included. |
|
|
|
Standard Sizes
|
|
Part
Number
|
Number
of
Rows
|
Panel
Height
H x L (in)
|
Number
of
Jacks
|
Cutout
Size
H x L (in)
|
Price
US Dollars |
|
JP(¤)00037
|
1
|
3-1/2 x 5-1/2
|
6
|
1-7/8 x 4-21/32
|
|
|
JP(¤)00038
|
2
|
5-3/16 x 5-1/2
|
12
|
3-9/16 x 4-21/32
|
|
|
JP(¤)00039
|
3
|
8-1/8 x 5-1/2
|
18
|
6-1/2 x 4-21/32
|
|
|
JP(¤)00040
|
1
|
3-1/2 x 10
|
12
|
1-7/8 x 9-1/4
|
|
|
JP(¤)00041
|
2
|
5-3/16 x 10
|
24
|
3-9/16 x 9-1/4
|
|
|
JP(¤)00042
|
3
|
8-1/8 x 10
|
36
|
6-1/2 x 9-1/4
|
|
|
¤ Insert
calibration code in Part Number (J, K, T, E, R, S, U)
|
Mounting Hole Spacing: 3/16" in from each side
to center of 13/64" hole (for #10 screw). |
|