Jack Panels and Accessories

Tempco's Jack Panels are made from rugged, .090" thick aluminum and allow for easy installation of multi-circuit thermocouple or RTD Quick Disconnect Jacks in your panel or housing. Panels can be manufactured with either a single calibration type or a mixed variety.

10" Bezel Jack Panel for Standard Thermocouple Connectors

Accepts standard plugs.
Jacks are ANSI color coded, glass filled nylon with a maximum service temperature of 400ºF (204ºC).
Panels are manufactured from rugged, .090" thick aluminum.
Brushed and anodized finishes are available at an additional cost. Consult TEMPCO with your requirements.
Panels are normally supplied unassembled with
all necessary hardware to assemble and install included. Can be furnished assembled at an additional cost.

Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

JP(¤)00001

1

3-1/2 x 10

12

1-7/8 x 9-1/4

JP(¤)00002

2

5-3/16 x 10

24

3-9/16 x 9-1/4

JP(¤)00003

3

8-1/8 x 10

36

6-1/2 x 9-1/4

JP(¤)00004

4

9-7/8 x 10

48

8-1/4 x 9-1/4

JP(¤)00005

5

12-3/4 x 10

60

11-1/8 x 9-1/4

JP(¤)00006

6

14-9/16 x 10

72

12-15/16 x 9-1/4

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U, N)

Mounting Hole Spacing: 3/16" in from each side to center of 13/64" hole (for #10 screw). Bezel Panel Jacks are retained by a spring clip which is installed from the rear of the panel. Wire may be attached after Jacks are installed in panel.

5" Bezel Jack Panel for Standard Thermocouple Connectors


Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

JP(¤)00007

1

3-1/2 x 5-1/2

6

1-7/8 x 4-21/32

JP(¤)00008

2

5-3/16 x 5-1/2

12

3-9/16 x 4-21/32

JP(¤)00009

3

8-1/8 x 5-1/2

18

6-1/2 x 4-21/32

JP(¤)00010

4

9-7/8 x 5-1/2

24

8-1/4 x 4-21/32

JP(¤)00011

5

12-3/4 x 5-1/2

30

11-1/8 x 4-21/32

JP(¤)00012

6

14-9/16 x 5-1/2

36

12-15/16 x 4-21/32

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U, N)


For Miniature Thermocouple Connectors

Designed to be space saving.
Complements modern miniature instrumentation.
Jack bodies are ANSI color coded, glass filled nylon with a maximum service
temperature of 400ºF (204ºC).
Panels are manufactured of rugged .090" thick aluminum.
Brushed and anodized finishes are available at an additional cost. Consult TEMPCO
with your requirements.
Panels are supplied unassembled for ease of wiring--all hardware to assemble is included.
 

Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

Price
US Dollars

JP(¤)00013

1

22-1/32 x 3-5/8

6

1-9/32 x 3-3/32

 

JP(¤)00014

2

4-5/16 x 3-5/8

12

2-15/16 x 3-3/32

 

JP(¤)00015

3

5-31/32 x 3-5/8

18

4-19/32 x 3-3/32

 

JP(¤)00016

4

7-5/8 x 3-5/8

24

6-1/4 x 3-3/32

 

JP(¤)00017

1

2-21/32 x 6-5/8

12

1-9/32 x 6-1/16

 

JP(¤)00018

2

4-5/16 x 6-5/8

24

2-15/16 x 6-1/16

 

JP(¤)00019

3

5-31/32 x 6-5/8

36

4-19/32 x 6-1/16

 

JP(¤)00020

4

7-5/8 x 6-5/8

48

6-1/4 x 6-1/16

 

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U)

 
 

Mounting Hole Spacing: 3/16" in from each side to center of 13/64" hole (for #10 screw).


Jack Panels for 3-pin Connectors

For Standard 3-pin Connectors

 For use with RTD's and shielded thermocouples requiring 3 wires.
 Will accept standard 3-Pin connectors.
 Jack bodies are ANSI color coded, glass filled nylon with a maximum service temperature of 400ºF (204ºC).
 Panels are manufactured of rugged .090" thick aluminum.
 Brushed and anodized finishes are available at an additional cost. Consult TEMPCO with your requirements.
 Panels are supplied unassembled for ease of wiring--all hardware to assemble is included.

 
Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

JP(¤)00021

1

3-1/2 x 5-1/4

6

2-3/32 x 4-15/32

JP(¤)00022

2

6-1/32 x 5-1/4

12

4-21/32 x 4-15/32

JP(¤)00023

3

8-19/32 x 5-1/4

18

7-9/32 x 4-15/32

JP(¤)00024

4

11-5/32 x 5-1/4

24

9-25/32 x 4-15/32

JP(¤)00025

1

3-1/2 x 9-3/4

12

2-3/32 x 8-31/32

JP(¤)00026

2

6-1/32 x 9-3/4

24

4-21/32 x 8-31/32

JP(¤)00027

3

8-19/32 x 9-3/4

36

7-9/32 x 8-31/32

JP(¤)00028

4

11-5/32 x 9-3/4

48

9-25/32 x 8-31/32

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U)

Mounting Hole Spacing: 3/16" in from each side to center of 13/64" hole (for #10 screw).

 
 
 

For Miniature 3-Pin Connectors

For use with RTD's and shielded thermocouples requiring 3 wires.   Complements modern miniature instrumentation.   Jack bodies are ANSI color coded, glass filled nylon with a maximum service temperature of 400ºF (204ºC).   Panels are manufactured of rugged .090" thick aluminum.   Brushed and anodized finishes are available at an additional cost. Consult TEMPCO with your requirements.   Panels are supplied unassembled for ease of wiring--all hardware to assemble is included.

Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

JP(¤)00029

1

2-15/16 x 4-3/4

6

1-9/16 x 4-5/32

JP(¤)00030

2

4-15/16 x 4-3/4

12

3-9/16 x 4-5/32

JP(¤)00031

3

6-15/16 x 4-3/4

18

5-9/16 x 4-5/32

JP(¤)00032

4

8-15/16 x 4-3/4

24

7-9/16 x 4-5/32

JP(¤)00033

1

2-15/16 x 9

12

1-9/16 x 8-15/32

JP(¤)00034

2

4-15/16 x 9

24

3-9/16 x 8-15/32

JP(¤)00035

3

6-15/16 x 9

36

5-9/16 x 8-15/32

JP(¤)00036

4

8-15/16 x 9

48

7-9/16 x 8-15/32

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U)
Mounting Hole Spacing: 3/16" in from each side to center of 13/64" hole (for #10 screw).


Accessories, Selector Switches -- Jacks

Selector Switches


 Available in 6 to 36 positions  2-Pole and 3-Pole circuits with "OFF" position  Silver plated blades and contacts with self-cleaning wiper action and low contact resistance  Terminals are silver plated brass with numbered circuits and polarity identification  "OFF" position has terminals available for shorting input circuit when using it with a digital meter (Not available on 3-Pole)  High impact GE noryl™ case
 

 

 

 

 





 



 

 

Number of
Positions

Circuit Type

Part 
Number

Size

6

2-Pole
Break Before Make

TCA-124-101

Size "A"

10

TCA-124-102

12

2-Pole
Make Before Break

TCA-124-103

18

TCA-124-104

20

TCA-124-105

24

2-Pole
Make Before Break

TCA-124-106

Size "B"

36

TCA-124-107

6

3-Pole
Make Before Break

TCA-124-108

12

TCA-124-109

18

TCA-124-110

24

TCA-124-111

 

Circular Panel Jacks


Example of Electrical Box Mount

Standard Jack Miniature Jack
  Available in standard and miniature sizes (2-pin only).
 Used where individual Jacks are required to fit in standard electrical knockouts.
 Standard Jack fits in 3/4" (1-1/8" dia.) electrical knockout.
 Miniature Jack fits in 1/2" (7/8" dia.) electrical knockout.
 Jacks are ANSI color coded with a maximum service temperature of 400ºF (204ºC).
 Both the standard and miniature Jacks install from the front of the panel with no additional hardware required.
ANSI
Calibration

Body Color

Part Number
Standard

Miniature

J

Black

TCA-102-167

TCA-102-174

K

Yellow

TCA-102-168

TCA-102-175

T

Blue

TCA-102-169

TCA-102-176

E

Purple

TCA-102-170

TCA-102-177

R/S

Green

TCA-102-171

TCA-102-178

Cu

White

TCA-102-172

TCA-102-179

N

Orange

TCA-102-173

--

 
Panel Jacks

All Panel Jacks have the same high quality features as their non-panel counterparts and include hardware for mounting.
Bezel Mount Standard Jack  

 

ANSI
Calibration

Body Color

Part 
Number

J

Black

TCA-102-137

K

Yellow

TCA-102-138

T

Blue

TCA-102-139

E

Purple

TCA-102-140

R/S

Green

TCA-102-141

Cu

White

TCA-102-142

N

Orange

TCA-102-180

Miniature Panel Jack -- 2-Pin  

ANSI
Calibration

Body Color

Part 
Number

J

Black

TCA-102-143

K

Yellow

TCA-102-144

T

Blue

TCA-102-145

E

Purple

TCA-102-146

R/S

Green

TCA-102-147

Cu

White

TCA-102-148

Standard 3-Pin Panel Jack  

 

ANSI
Calibration

Body Color

Part 
Number

J

Black

TCA-102-149

K

Yellow

TCA-102-150

T

Blue

TCA-102-151

E

Purple

TCA-102-152

R/S

Green

TCA-102-153

Cu

White

TCA-102-154

Miniature Panel Jack -- 3-Pin  

 

ANSI
Calibration

Body Color

Part 
Number

J

Black

TCA-102-155

K

Yellow

TCA-102-156

T

Blue

TCA-102-157

E

Purple

TCA-102-158

R/S

Green

TCA-102-159

Cu

White

TCA-102-160

Panel Mount Standard Jab-In Jack

 

ANSI
Calibration

Body Color

Part 
Number

J

Black

TCA-102-161

K

Yellow

TCA-102-162

T

Blue

TCA-102-163

E

Purple

TCA-102-164

R/S

Green

TCA-102-165

Cu

White

TCA-102-166


Jack Panels -- FS Box & Custom

For FS Box

Panel Only

Panel and
Box Assembly

 Jack Panels are designed to be used with standard FS Style boxes.
 Panels are manufactured of rugged .090" thick aluminum.
 Panels are designed to accept the safest maximum number of Jacks--see table.
 Available for Standard and Miniature Jacks, 2-pin or 3-pin.
 Rated for a maximum of 400ºF (204ºC).
 Panels measure 2-13/16" high x 4-1/2" long.

Jack
Style

Part
Number

Number of
Jacks

Standard 2 Pin
Bezel Mount

JP(¤)00043

4

Standard 2 Pin
Jab-In Mount

JP(¤)00044

4

Standard 3 Pin

JP(¤)00045

4

Miniature 2 Pin

JP(¤)00046

6

Miniature 3 Pin

JP(¤)00047

4

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U)


Custom Made 19" Rack Panels


Standard Features

 
Panels are made of .090" thick aluminum with a smooth mill finish.
 All panels have slotted holes positioned at E.I.A. standard spacing.
 Panels are available with any of the standard or miniature Panel Jacks shown in this section.
 Rack Panels come in standard heights of 3-1/2", 5-1/4", 7", and 8-1/4".
 Panels are supplied unassembled for ease of wiring--all hardware to assemble is included.


Jab-In Style Termination

To help ease installation
Optional Ratchet Screwdriver
Part Number:
TUL-101-101
 
    

Accepts Standard Plugs.
 Jacks will accept up to 14 gauge wire.
 Jack bodies are ANSI color coded, glass filled nylon with a maximum service temperature of 400ºF (204ºC).
 Panels are manufactured of rugged .090" thick aluminum.
 Brushed and anodized finishes are available at an additional cost. Consult TEMPCO with your requirements.
 Jack rows are placed further apart than standard Jack Panels for ease of termination.
 Panels are supplied unassembled for ease of wiring--all hardware to assemble is included.

 

Standard Sizes

Part
Number

Number
of
Rows

Panel
Height
H x L (in)

Number
of
Jacks

Cutout
Size
H x L (in)

Price
US Dollars

JP(¤)00037

1

3-1/2 x 5-1/2

6

1-7/8 x 4-21/32

 

JP(¤)00038

2

5-3/16 x 5-1/2

12

3-9/16 x 4-21/32

 

JP(¤)00039

3

8-1/8 x 5-1/2

18

6-1/2 x 4-21/32

 

JP(¤)00040

1

3-1/2 x 10

12

1-7/8 x 9-1/4

 

JP(¤)00041

2

5-3/16 x 10

24

3-9/16 x 9-1/4

 

JP(¤)00042

3

8-1/8 x 10

36

6-1/2 x 9-1/4

 

¤ Insert calibration code in Part Number (J, K, T, E, R, S, U)

Mounting Hole Spacing: 3/16" in from each side
to center of 13/64" hole (for #10 screw).