Style T1 Transition to Lead wire

"L"

1-1/2" 
Ref

Lead Length 
1 ft. Std.
 
Design Features
* Stainless steel transition is brazed to thermocouple sheath.
* Maximum continuous operating temperature for the standard transition is 300ºF (149ºC). A high temperature transition 1000ºF(538ºC) maximum can be provided by ordering Special Requirement Option H in Box 11.
* Standard lead wire termination is 1" split leads.
* TEMPCO offers an optional Strain Relief Spring--Please Specify.
* Transition Diameters are 3/16" for .020" to .032" diameter sheath, 1/4" O.D. for .040" to.188" diameter sheath and 1/2" O.D. for all sheath diameters above .190".
 

 

How To Order
Thermocouples are offered with the options listed in the worksheet below. Create an ordering code by filing in the boxes with the appropriate number and/or letter designation for your requirements, and a part number will be assigned.

Please contact Thermal Tech Equipment  for further assistance.

Toll Free (800) 444-2770

 

  1 2 3 4 5 6 7 8 9 10 11
T 1                            
Design Style                            
Calibration Code BOX 1
ANSI Standard
Tolerances
J K E T N R S B
Special Tolerances 3 4 5 6 7      
Number of Conductors BOX 2
2 = Standard for Single Thermocouple
4 = Duplex T/C
Insulation BOX 3
M = 94% Min. MgO
H = 99.4% Min. MgO
A = 99.6% Alumina
Sheath Material BOX 4
A = Alloy 600
B = 304 SS
C = 316 SS
Sheath O.D. BOX 5
A = .020" ±.001
B = .032" ±.001
C = .040" ±.001
D = .063" ±.001
E = .093" ±.002
F = .125" ±.002
G = .188" ±.002
H = .250" +.003/-.002
J = .313" +.003/-.002
K = .375" +.003/-.002
L = 1.0mm ±.03
N = 1.5mm ±.03
P = 2.0 mm ±.03
Q = 3.0 mm ±.03
R = 4.5 mm ±.05
S = 6.0 mm +.07/-.05
T = 8.0 mm +.07/-.05
V = 9.0 mm +.07/-.05

 

Sheath Length "L" BOX 6
Whole inches 01 to 99
Lengths over 99 in. consult TEMPCO
Junction BOX 7
  Grounded Ungrounded Exposed
Single G U E
Dual, common 4 5 6
Dual, isolated -- 7 8
Lead Wire Length BOX 8
In inches 001 to 999
12" (012) Standard
Lead Wire Construction BOX 9
Fiberglass Solid Standard
S
Overbraid
B
Flex Armor
A

Depending on availability .040" to .188" uses 24 gauge lead wire.
.188" to .375" O.D. thermocouples use 20 gauge lead wire
depending on availability and insulation type.

Lead Wire Termination BOX 10
A = Standard Male Plug
B = Standard Female Jack
C = Std. Plug with 
Mating Conn.
D = Miniature Male Plug
E = Miniature Female Jack
F = Miniature Plug with Mating Jack
G = Standard--1.0 in. Split Leads
H = 1.0 in. Split Leads with 
Spade Lugs
J = 1.0 in. Split Leads with BX connector and Spade Lugs
Special Requirements BOX 11
H = High temp potting. If none, enter "0"
If others required, consult TEMPCO