Style T4 Stripped Cold End

Design Features
* Standard strip length is 1/2 inch.
* Stripped end sealed with resin to inhibit moisture penetration.
* Duplex available from 0.063" diameter to 0.375" diameter.
   1/2"   "L"

 

How To Order
Thermocouples are offered with the options listed in the worksheet below. Create an ordering code by filing in the boxes with the appropriate number and/or letter designation for your requirements, and a part number will be assigned.

Please contact Thermal Tech Equipment  for further assistance.

Toll Free (800) 444-2770

 

 

  1 2 3 4 5 6 7 8 9
T 4                    
Design Style                    
Calibration Code BOX 1
ANSI Standard
Tolerances
J K E T N R S B
Special Tolerances 3 4 5 6 7      
Number of Conductors BOX 2
2 = Standard for Single Thermocouple
4 = Duplex T/C
Insulation BOX 3
M = 94% Min. MgO
H = 99.4% Min. MgO
A = 99.6% Alumina
Sheath Material BOX 4
A = Alloy 600
B = 304 SS
C = 316 SS
Sheath O.D. BOX 5
B = .032" ±.001
C = .040" ±.001
D = .063" ±.001
E = .092" ±.001
F = .125" ±.002
G = .188" ±.002
H = .250" +.003/-.002
J = .313" +.003/-.002
K = .375" +.003/-.002
L = 1.0mm ±.03
N = 1.5mm ±.03
P
= 2.0 mm ±.03
Q = 3.0 mm ±.03
R = 4.5 mm ±.05
S = 6.0 mm +.07/-.05
T = 8.0 mm +.07/-.05
V = 9.0 mm +.07/-.05
Sheath Length "L" BOX 6
Whole inches 01 to 99
Lengths over 99 in. consult TEMPCO
Junction BOX 7
  Grounded Ungrounded Exposed
Single G U E
Dual, common 4 5 6
Dual, isolated -- 7 8
Strip Length BOX 8
0" to 3"
Whole inches. 1/2" standard
Special Requirements BOX 9

If none, enter "0"
If others required, consult TEMPCO